2024

Vol.31 No.2

Editorial Office

Review

  • Journal of the Microelectronics and Packaging Society
  • Volume 27(2); 2020
  • Article

Review

Journal of the Microelectronics and Packaging Society 2020;27(2):39-44. Published online: Aug, 25, 2020

CNT-Ni-Fabric Flexible Substrate with High Mechanical and Electrical Properties for Next-generation Wearable Devices

  • Hyung Gu Kim1, Ho Kyun Rho2, Anna Cha1, Min Jung Lee1, and Jun-Seok Ha1,2,†
    1Department of Advanced Chemicals & Engineering, Chonnam National University, 2Energy Convergence Core Facility, Chonnam National University
Corresponding author E-mail: jsha@jnu.ac.kr
Abstract

최근 웨어러블 장치에 적용하기 위한 유연성 기판에 대한 연구가 활발히 진행되고 있다. 특히, 유연성 기판중 의복에 웨어러블 장치를 적용하기 위한 전도성 섬유기판에 대한 연구가 진행되고 있다. 본연구에서는, 면섬유 기판 표면 에 CNT와 Pd복합 용액을 스프레이 법을 이용하여 형성하였고, 무전해 도금법을 이용하여 금속층을 도금하였다. 도금된 섬유기판의 형상을 분석하기 위하여 SEM 장비를 이용하였고, CNT를증착한 섬유기판의 표면에 Ni 레이어가 형성된것 을 확인하였다. EDS 분석을 통하여 섬유기판의 표면에 형성된 물질이 Ni임을 알 수 있었다. 전기적 특성을 확인하기 위 하여 4-point probe로 무전해 도금을 진행한 섬유기판의 표면저항 및 저항 분포를 확인하기 위한 맵핑을 진행하였다. 무 전해도금의진행시간이길어질수록전도성이 향상되었음을 확인할수있었고, 표면위치별저항의분포가 균일함을알 수있었다. 인장력, 굽힘, 뒤틀림 시험을 통하여 기계적 스트레스로 인한 저항변화를 측정하였다. 그결과 도금 시간이길 어질수록 유연성 기판의 저항변화가 점점 사라지는 것을 확인하였다. UTM(Universal testing machine)을이용하여 도금 시간 변화에 대한 무전해 도금 기판의 기계적 특성 향상 여부에 대하여 분석하였다. 인장강도는 무전해 도금을 2 시간동 안진행한 전도성 섬유기판의 경우, 면섬유 기판보다약 16 MPa 증가하였다. 이러한 결과들을 토대로 Ni-CNT-Fabric 유 연기판은 의류 일체형 전도성 기판으로 이용되기에 충분함을 확인하였고, 이러한 연구 결과는 유연기판, 웨어러블 디바 이스뿐만 아니라 유연성이 필요한 배터리, 촉매, 태양전지 등에 적용되어 발전에 기여할 수 있을 것으로 기대한다.
Recently, numerous researches are being conducted in flexible substrate to apply to wearable devices. Particularly, Conductive substrate researches that can implement the wearable devices on clothing are massive. In this study, we formed fiber substrate spraying CNT and Pd mixed solution on it and plated metal layer with electroless plating. Used SEM equipment and EDS analysis to analysis structure of the plated fiber substrate and discovered Ni layer was created. For check electrical properties, mapping was performed to check surface resistance and distribution of resistance of electroless plated fiber substrate with 4-point probe. It was confirmed that conductivity was improved as the duration of electroless plating was increased, and it was found that distribution of resistance by surface location was uniform. Changes in resistance due to mechanical stress were measured through tensile, bending, and twisting tests. As a result, it was confirmed that resistance change of flexible substrate gradually disappeared as plating time increased. Using UTM (Universal testing machine), it was analyzed mechanical properties of the electroless plated substrate with respect to changes in plating time were improved. In the case of conductive fiber substrate in which electroless plating was performed for 2 hours, tensile strength was increased by 16 MPa than fiber substrate. Based on these results, we found that Ni- CNT-Fabric flexible substrate is adequate for clothing-intergrated conductive substrate and we positively expect that this experiment shows flexible substrate can adapt to and develop not only a wearable device technology but also other fields needing flexibility such as battery, catalyst and solar cell.

Keywords Wearable device, Conductive fiber, Flexible substrate, CNT spray, Ni electroless plating